Environmental engineering follows water on one journey: from the source, through treatment, to the tap, then down the drain, through sewage treatment and back to the river. If you study the subject in that order, each topic explains the next one.
The topics follow the order of the official GATE Civil Engineering syllabus. Design values are those of the CPHEEO manuals and Indian Standards as taught in standard textbooks. For the other subjects, see the GATE, ESE and SSC JE preparation guide.
What the syllabus asks
| Exam | Syllabus wording |
|---|---|
| GATE CE, Water and Wastewater | Basics of water quality standards: physical, chemical and biological parameters; water quality index; unit processes and operations; water requirement; water distribution system; drinking water treatment. Sewerage system design, quantity of domestic wastewater, primary and secondary treatment; effluent discharge standards; sludge disposal; reuse of treated sewage |
| GATE CE, Air Pollution | Types of pollutants, their sources and impacts, air pollution control, air quality standards, air quality index and limits |
| GATE CE, Municipal Solid Wastes | Characteristics, generation, collection and transportation of solid wastes; engineered systems for solid waste management: reuse and recycle, energy recovery, treatment and disposal |
| ESE Civil Paper II | Water supply engineering: sources, quality standards, treatment, distribution. Wastewater engineering: collection, treatment, sludge management and disposal. Solid waste management. Air and noise pollution. Environmental impact assessment |
| SSC JE | Quality of water, source of water supply, purification of water, distribution of water, need of sanitation, sewerage systems, circular sewer, oval sewer, sewer appurtenances, sewage treatments, surface water drainage, solid waste management, types of pollution and their effects |
1. Water demand and population forecasting
In simple words: Before a water supply scheme is designed, the engineer must know how many people it will serve 20 or 30 years from now and how much water each will use. Demand is not steady: it peaks on hot days and at certain hours, and a fire needs a large flow for a short time.

Where you see it: The capacity of a treatment plant is fixed by the maximum daily demand. The distribution pipes are sized for the maximum hourly demand, or for the maximum daily demand plus fire flow, whichever is more.
| Quantity | Formula or value |
|---|---|
| Domestic demand (IS 1172, with full flushing) | 135 litres per person per day |
| Arithmetic increase method | Pn = P0 + n x̄ |
| Geometric increase method | Pn = P0 (1 + r/100)n |
| Incremental increase method | Pn = P0 + n x̄ + n (n + 1) ȳ / 2 |
| Maximum daily demand | 1.8 × average daily demand |
| Maximum hourly demand | 1.5 × maximum daily demand = 2.7 × average |
| Coincident draft | Maximum daily demand + fire demand |
| Fire demand, Kuichling’s formula | Q = 3182 √P litres per minute, with P in thousands |
x̄ is the average increase in population per decade, ȳ the average of the incremental increases, r the average percentage growth per decade and n the number of decades. The arithmetic method suits old, settled cities and gives the lowest forecast. The geometric method suits young, fast-growing towns and gives the highest.
Example. A town has 50 000 people today. Its population has grown by an average of 8000 per decade. Forecast the population after two decades by the arithmetic method and the average daily demand at 135 litres per person.
- P = 50 000 + 2 × 8000 = 66 000.
- Average daily demand = 66 000 × 135 = 8.91 × 106 litres = 8.91 MLD.
- Maximum daily demand = 1.8 × 8.91 = 16.0 MLD. The treatment plant is sized for this.
2. Water quality parameters and standards
In simple words: Water is tested for what you can see and smell (physical), what is dissolved in it (chemical) and what lives in it (biological). Drinking water standards set a limit for each.
Where you see it: A village borewell with fluoride above 1.5 mg/L causes mottled teeth and bone damage, so it needs defluoridation. Hard water does not harm health, but it wastes soap and leaves scale in boilers and geysers.
| Parameter | Acceptable limit (IS 10500:2012) | Permissible limit if there is no other source |
|---|---|---|
| pH | 6.5 to 8.5 | No relaxation |
| Turbidity | 1 NTU | 5 NTU |
| Total dissolved solids | 500 mg/L | 2000 mg/L |
| Total hardness, as CaCO3 | 200 mg/L | 600 mg/L |
| Chloride | 250 mg/L | 1000 mg/L |
| Fluoride | 1.0 mg/L | 1.5 mg/L |
| Nitrate | 45 mg/L | No relaxation |
| Arsenic | 0.01 mg/L | See the current standard |
| Free residual chlorine | 0.2 mg/L minimum | 1.0 mg/L |
| E. coli | Not detectable in any 100 mL sample |
| Quantity | Formula |
|---|---|
| Concentration as CaCO3 | Concentration of the ion × 50 / its equivalent weight |
| Total hardness as CaCO3 | [Ca²⁺] × 50/20 + [Mg²⁺] × 50/12 |
| Carbonate (temporary) hardness | The smaller of total hardness and total alkalinity |
| Non-carbonate (permanent) hardness | Total hardness − carbonate hardness |
- Temporary hardness is caused by bicarbonates and is removed by boiling or by adding lime. Permanent hardness is caused by sulphates and chlorides and needs the lime-soda, zeolite or ion exchange process.
- Excess nitrate causes blue baby disease (methaemoglobinaemia) in infants.
- Coliform bacteria are used as indicator organisms: they are harmless themselves but show that sewage, and so possibly disease organisms, has entered the water.
Example. A water sample has 40 mg/L of calcium and 24 mg/L of magnesium. Find the total hardness as CaCO3.
- From calcium: 40 × 50 / 20 = 100 mg/L.
- From magnesium: 24 × 50 / 12 = 100 mg/L.
- Total hardness = 200 mg/L as CaCO3, which is just at the acceptable limit.
3. Drinking water treatment
In simple words: Raw water is cleaned in steps, each removing smaller impurities than the one before: screens take out floating matter, settling tanks take out heavier particles, coagulation gathers fine particles into lumps that settle, filters remove what is left, and chlorine kills the germs.
Where you see it: Every city water works follows this chain. The usual order is screening, aeration, coagulation and flocculation, sedimentation, filtration and disinfection.
| Quantity | Formula or typical value |
|---|---|
| Settling velocity of a small particle (Stokes’ law) | vs = g (G − 1) d² / (18 ν) |
| Surface overflow rate | SOR = Q / (plan area of the tank) |
| Detention time | t = Volume / Q |
| Removal of particles slower than the SOR | Fraction removed = vs / SOR |
| Velocity gradient in a flocculator | G = √[P / (μ V)] |
| Rate of filtration, slow sand filter | 100 to 200 litres per m² per hour |
| Rate of filtration, rapid sand filter | 3000 to 6000 litres per m² per hour |
| Chlorine demand | Chlorine dose − residual chlorine |
- A particle is fully removed in an ideal settling tank if its settling velocity is equal to or greater than the surface overflow rate. The depth of the tank does not matter in theory.
- Alum is the common coagulant. It works best at a pH of about 6.5 to 8.5 and needs alkalinity in the water.
- Slow sand filters remove bacteria very well but need a large area. Rapid sand filters are compact and are cleaned by backwashing.
- Chlorine in water forms hypochlorous acid (HOCl), the main disinfectant. It is more effective at lower pH. Breakpoint chlorination is the dose beyond which added chlorine appears as free residual.
Example. A sedimentation tank treats 6000 m³ of water per day. Design it for a surface overflow rate of 20 m³/m²/day and a detention time of 3 hours.
- Plan area = Q / SOR = 6000 / 20 = 300 m².
- Volume = Q × t = 6000 × 3 / 24 = 750 m³.
- Depth = 750 / 300 = 2.5 m. A tank 30 m long and 10 m wide would suit.
Each unit is described in water treatment processes.
4. Sewerage: quantity of sewage and design of sewers
In simple words: Most of the water supplied to a town comes back as sewage. Sewers are pipes that carry it by gravity, usually flowing partly full. They must be laid steep enough for the flow to carry the solids along, but not so steep that the flow scours the pipe.
Where you see it: A sewer laid too flat chokes with silt and has to be cleaned again and again. This is the most common defect in sewer lines and the reason slopes are checked carefully with a level during laying.
| Quantity | Value or formula |
|---|---|
| Sewage flow | About 80% of the water supplied |
| Self-cleansing velocity (minimum) | About 0.6 m/s at design flow, never below 0.45 m/s |
| Maximum (non-scouring) velocity | About 3 m/s |
| Flow in a sewer | Manning’s equation, V = (1/n) R2/3 S1/2 |
| Depth of flow | Sewers are designed to run half to three-quarters full at peak flow |
In a separate system, sewage and storm water have their own pipes. In a combined system one pipe carries both. An egg-shaped sewer keeps a good velocity at low flows and so suits combined systems. Storm drains are covered in types of stormwater drainage systems.
5. Characteristics of sewage: BOD and COD
In simple words: Sewage is mostly water with a small amount of organic matter. Bacteria feed on that matter and use up dissolved oxygen as they do. The oxygen they need is the biochemical oxygen demand (BOD). It is the standard measure of how strong, or how polluting, a sewage is.
Where you see it: If raw sewage with a high BOD enters a river, bacteria take the oxygen from the water and fish die. A treatment plant is judged by how far it brings the BOD down before discharge.
| Quantity | Formula or value |
|---|---|
| BOD exerted in t days | BODt = L0 (1 − e−kt) |
| Standard test | 5 days at 20°C (BOD5) |
| Rate constant at another temperature | kT = k20 × 1.047(T − 20) |
| BOD from a diluted sample | (Initial DO − final DO) × dilution factor |
| Population equivalent | Total BOD load per day / 0.08 kg per person per day |
| Concentration after mixing with a river | C = (Qs Cs + Qr Cr) / (Qs + Qr) |
- L0 is the ultimate BOD. If k is given to base 10, use 10−kt in place of e−kt; the base-e value is 2.303 times the base-10 value.
- COD is measured with a strong chemical oxidant in about three hours. It is always greater than BOD, because it also oxidises matter that bacteria cannot break down.
- After sewage enters a river, the dissolved oxygen first falls and then recovers. This dip is the oxygen sag curve, described by the Streeter-Phelps equation.
Example. A sewage has an ultimate BOD of 300 mg/L and a rate constant of 0.23 per day (base e) at 20°C. Find its 5-day BOD.
- BOD5 = 300 × (1 − e−0.23 × 5) = 300 × (1 − 0.317) = 205 mg/L.
- About two-thirds of the ultimate demand is exerted in the first five days.
6. Sewage treatment and sludge
In simple words: Sewage treatment copies what a river does naturally, but faster and inside tanks. Primary treatment lets the solids settle. Secondary treatment grows bacteria that eat the dissolved organic matter. The bacteria are then settled out as sludge.
Where you see it: The activated sludge process is used in most city sewage treatment plants. Small communities use oxidation ponds, and single houses without a sewer use septic tanks followed by a soak pit.
| Quantity | Formula or value |
|---|---|
| Primary settling tank | Removes about 60% to 65% of suspended solids and 30% to 35% of BOD |
| Hydraulic retention time of the aeration tank | HRT = V / Q |
| Food to microorganism ratio | F/M = Q S0 / (V X) |
| Sludge age (mean cell residence time) | θc = V X / [Qw Xr + (Q − Qw) Xe] |
| Sludge volume index | SVI = settled volume in 30 minutes (mL/L) × 1000 / MLSS (mg/L) |
| Volume of sludge and its moisture content | V1 (100 − p1) = V2 (100 − p2) |
S0 is the BOD entering the aeration tank and X is the concentration of microorganisms in it, the MLSS. An SVI of about 50 to 150 mL/g shows a sludge that settles well; a much higher value means bulking sludge. Trickling filters do the same job with bacteria growing on a bed of stone or plastic media. Sludge is thickened, digested, dewatered and then used as manure or sent to a landfill. Treated sewage is reused for gardening, flushing, industrial cooling and irrigation.
Example. An aeration tank of 1250 m³ receives 5000 m³/day of sewage with a BOD of 200 mg/L. The MLSS is 2000 mg/L. Find the retention time and the F/M ratio.
- HRT = V / Q = 1250 / 5000 = 0.25 day = 6 hours.
- F/M = Q S0 / (V X) = 5000 × 200 / (1250 × 2000) = 0.4 per day.
- Both values are in the usual range for a conventional activated sludge plant.
Sludge volume in practice. Reducing the moisture content of a sludge from 98% to 96% looks like a small change, but the solids content doubles from 2% to 4%, so the volume is halved. This is why thickening comes before every other sludge process.
Effluent standards. The general standards for discharge into inland surface water commonly quoted in textbooks are BOD not more than 30 mg/L and suspended solids not more than 100 mg/L. Newer standards for sewage treatment plants are stricter, so check the current notification for design work.
7. Air pollution
In simple words: Air pollutants are either released directly, such as smoke, dust and sulphur dioxide (primary pollutants), or formed in the air from other pollutants, such as ozone and smog (secondary pollutants). How far they spread depends on how the air temperature changes with height.
Where you see it: In winter, a layer of warm air often sits above cold air near the ground. This inversion acts like a lid, pollutants cannot rise, and cities see their worst smog.
| Control device | Removes |
|---|---|
| Gravity settling chamber | Coarse particles, larger than about 50 µm |
| Cyclone separator | Particles larger than about 10 µm |
| Fabric (bag) filter | Fine particles, with very high efficiency |
| Electrostatic precipitator | Very fine particles; used in thermal power plants and cement works |
| Wet scrubber | Particles and soluble gases together |
| Pollutant (24-hour average) | National ambient air quality standard, 2009 |
|---|---|
| PM10 | 100 µg/m³ |
| PM2.5 | 60 µg/m³ |
| Sulphur dioxide | 80 µg/m³ |
| Nitrogen dioxide | 80 µg/m³ |
- The dry adiabatic lapse rate is 9.8°C per km. If the actual temperature falls faster than this with height, the air is unstable and pollutants mix well (looping plume). If temperature rises with height, there is an inversion and the plume spreads flat (fanning).
- The Indian air quality index has six classes: Good (0 to 50), Satisfactory (51 to 100), Moderate (101 to 200), Poor (201 to 300), Very Poor (301 to 400) and Severe (401 to 500).
- Sulphur dioxide and nitrogen oxides cause acid rain. Carbon monoxide reduces the oxygen-carrying capacity of blood.
The health effects of fine particles are explained in understanding PM2.5.
8. Municipal solid waste
In simple words: Solid waste is everything a town throws away that is not carried off by water. Managing it means collecting it, recovering what is useful, and disposing of the rest so that it does not pollute land, water or air.
Where you see it: A sanitary landfill is not an open dump. The waste is spread in layers, compacted and covered with soil every day. A liner at the bottom stops leachate reaching the groundwater, and pipes collect the methane the waste gives off.
- Order of preference: reduce, reuse, recycle, recover energy, and only then dispose.
- Composting: bacteria turn the organic part of the waste into manure. It works best with a carbon to nitrogen ratio of about 30 and a moisture content of about 50% to 60%.
- Incineration: burning at high temperature. It reduces the volume by about 90% but needs waste with a good heating value and proper control of the flue gas.
- Sanitary landfill: the final disposal for whatever remains. Leachate and landfill gas (mainly methane and carbon dioxide) must be managed.
- Density of waste increases at each stage: loose in the bin, denser in the collection vehicle and densest in the compacted landfill.
9. Noise pollution (ESE and SSC JE)
| Quantity | Formula or value |
|---|---|
| Sound pressure level | L = 20 log10(P / P0) decibels, with P0 = 20 µPa |
| Two equal sources together | The level rises by 3 dB |
| Doubling the distance from a point source | The level falls by 6 dB |
Decibels cannot be added directly. Two machines of 80 dB each give 83 dB together, not 160 dB.
Common mistakes
- Mixing the base of the BOD rate constant. Check whether k is given to base e or base 10.
- Adding hardness of calcium and magnesium in mg/L directly, without converting each to mg/L as CaCO3.
- Using the average demand to size a treatment plant or a pipe. Plants use the maximum daily demand; pipes use the maximum hourly demand or the coincident draft.
- Forgetting to convert MLD to m³/day, or litres per hour to m³ per day, before finding an area or a volume.
- Putting the population into the fire demand formula in actual numbers instead of thousands.
- Treating the surface overflow rate and the detention time as the same thing. One fixes the plan area and the other fixes the volume.
Frequently asked questions
Which topics of environmental engineering are most important for GATE?
BOD calculations, sedimentation tank design, hardness and alkalinity, the activated sludge process (F/M, sludge age, SVI), chlorination and population forecasting give most of the numerical questions. Air pollution and solid waste usually give short, direct questions.
Do I need to remember the drinking water standards?
Yes, the main ones in the table above: pH, turbidity, TDS, hardness, chloride, fluoride and nitrate. They are asked directly, especially in SSC JE and state exams.
What is the difference between BOD and COD?
BOD is the oxygen that bacteria need to break down the biodegradable organic matter, measured over five days. COD is the oxygen needed to oxidise nearly all organic matter chemically, measured in a few hours. COD is always higher, and the ratio of BOD to COD shows how easily a waste can be treated biologically.
Is noise pollution in the GATE syllabus?
It is not listed in the current GATE Civil Engineering syllabus, which covers air pollution and municipal solid waste. It is part of the ESE syllabus and is asked in state exams, so learn the decibel formula and the rule for adding sound levels.
Unlock an ad-free experience plus a growing library of ready-to-use civil-engineering calculators, IS-code cheat-sheets and formula PDFs. From just ₹99.




