Isolated Footing Design as per IS 456: Step-by-Step Solved Example + Free Checker

A complete isolated footing design to IS 456:2000: sizing, bending, one-way and punching shear, development length, bar bending schedule and a free footing checker.

An isolated footing is the first RCC member most civil engineers design on their own. The arithmetic is short, but four separate checks govern it: bearing on soil, bending, one-way shear and punching shear. In practice the depth is almost always set by shear, not by bending. This guide works through a complete design to IS 456:2000, with every clause reference. It shows a trial depth that fails, explains why, and ends with a reinforcement detail, a bar bending schedule and a free checker you can use on your own footing.

Isolated footing design: the answer in one table
A 400 × 400 mm column carrying 1200 kN (service) on soil with SBC 200 kN/m², using M20 and Fe500, needs a 2.6 m × 2.6 m footing, 600 mm deep, with 12 mm bars @ 125 mm c/c both ways at the bottom.
Footing size2.6 m × 2.6 m (6.76 m²)
Net factored upward pressure266 kN/m²
Design moment at column face419 kN·m
Effective depth / overall depth532 mm / 600 mm
Steel required / provided1874 / 2262 mm² (20 bars of 12 mm)
Governing checkOne-way shear (0.284 ≤ 0.291 N/mm²)
All values are calculated in the steps below and cross-checked with the checker on this page. Use them to learn the method; your own footing needs its own loads and soil report.
Construction site with sloped isolated column footings, column starter bars and tie beams curing under wet hessian
Isolated footings on a real site: each column stands on its own sloped footing, tie beams cure under wet hessian and a pump keeps the pits dry. The worked example below designs a flat (pad) footing. Photo: Pexels.

Design data

Column400 mm × 400 mm, square
Axial service load, P1200 kN (dead + live)
Safe bearing capacity (SBC)200 kN/m²
ConcreteM20 (fck = 20 N/mm²)
SteelFe500 (fy = 500 N/mm²)
Clear cover50 mm (IS 456 cl. 26.4.2.2, footings)
Load factor1.5 (IS 456 Table 18)

Step 1: Size the footing for soil bearing

Size the plan area with service loads, not factored loads, because SBC is itself a service-level value. Allow about 10% for the footing’s self-weight and backfill.

  • Area required = 1.10 × 1200 / 200 = 6.6 m²
  • Side = √6.6 = 2.57 m → adopt B = 2.6 m, area = 6.76 m²
  • Check once D is known: (1200 + 6.76 × 0.6 × 25) / 6.76 = 192.5 kN/m² ≤ 200 ✓

Step 2: Net factored upward pressure

For bending and shear, use the factored column load only. The footing’s own weight acts straight down on the soil it sits on, so it does not bend the slab.

Building Estimate & BOQ Excel Kit cover
📚 Recommended Download
Building Estimate & BOQ Excel Kit
Type your building dimensions — get quantities, materials, a priced BOQ and cost per sq ft. 6 linked sheets, IS 1200-style measurement, editable rates.
✔ Editable Excel  ·  ✔ Instant download  ·  ✔ Lifetime access
  • Pu = 1.5 × 1200 = 1800 kN
  • qu = 1800 / 6.76 = 266.3 kN/m²
Plan and section of a 2.6 m square isolated footing showing the bending section at the column face, one-way shear section at d and punching perimeter at d/2
Critical sections for the worked example, drawn to scale (IS 456 cl. 31.6 and 34.2).

Step 3: Bending moment at the column face

IS 456 cl. 34.2.3.2 places the critical section for bending at the face of the column. Each side of the footing behaves as a cantilever projecting from that face.

  • Cantilever a = (2.6 − 0.4) / 2 = 1.1 m
  • Mu = qu × B × a² / 2 = 266.3 × 2.6 × 1.1² / 2 = 418.8 kN·m
  • Depth needed for bending alone (Fe500, Mu,lim = 0.133 fck b d²): d = √(418.8 × 10⁶ / (0.133 × 20 × 2600)) = 246 mm

246 mm looks small, and that is the trap. Shear will need roughly twice this depth, so never stop at the bending check.

Step 4: Trial depth 550 mm, and why it fails

Take D = 550 mm. With 50 mm cover and 12 mm bars in two layers, the average effective depth is d = 550 − 50 − 1.5 × 12 = 482 mm.

  • Punching shear (cl. 31.6, perimeter at d/2 from the face): side = 400 + 482 = 882 mm, b0 = 3528 mm. V = 266.3 × (6.76 − 0.882²) = 1593 kN. τv = 1593 × 10³ / (3528 × 482) = 0.94 N/mm² ≤ ks × 0.25√20 = 1.12 ✓
  • Steel: Ast required = 2085 mm²; 12 mm @ 130 mm gives 20 bars = 2262 mm², pt = 0.18%.
  • One-way shear (cl. 34.2.4.1(a), section at d from the face): distance to edge = 1.1 − 0.482 = 0.618 m, V = 266.3 × 2.6 × 0.618 = 428 kN. τv = 428 × 10³ / (2600 × 482) = 0.341 N/mm². From Table 19 at pt = 0.18%, τc = 0.304 N/mm². ✗ Fails.

Punching passes comfortably but one-way shear fails. Footings carry no shear stirrups, so there are only two fixes: make the slab deeper, or add steel to raise pt and with it τc. More 12 mm bars at 100 mm c/c would just pass (τc = 0.340). But that is 25 bars each way to save 50 mm of depth, and the margin is razor-thin. A deeper slab is the better design.

Step 5: Final depth 600 mm, all checks

D = 600 mm, d = 600 − 50 − 18 = 532 mm.

Flexural steel (Annex G)

  • Ast = 0.5 (fck/fy) [1 − √(1 − 4.6 Mu / (fck b d²))] b d = 1874 mm²
  • Minimum (cl. 34.5.1 → 26.5.2.1): 0.12% × 2600 × 600 = 1872 mm²
  • Provide 12 mm @ 125 mm c/c: (2600 − 100 − 12) / 125 + 1 = 20 bars → 2262 mm² ✓. Spacing 125 mm ≤ min(3d, 300) ✓
  • For a square footing the steel is spread uniformly across the full width in both directions (cl. 34.3.1(a)).

One-way shear (cl. 34.2.4.1(a))

  • V = 266.3 × 2.6 × (1.1 − 0.532) = 393.2 kN; τv = 393.2 × 10³ / (2600 × 532) = 0.284 N/mm²
  • pt = 100 × 2262 / (2600 × 532) = 0.164% → τc = 0.291 N/mm² (Table 19, interpolated) ✓

Punching shear (cl. 31.6.1 and 31.6.3)

  • Critical perimeter side = 400 + 532 = 932 mm, b0 = 3728 mm
  • V = 266.3 × (6.76 − 0.932²) = 1568.7 kN; τv = 1568.7 × 10³ / (3728 × 532) = 0.791 N/mm²
  • ks = 0.5 + βc = 1.5 → limited to 1.0; τc = 1.0 × 0.25√20 = 1.118 N/mm² ✓

Development length (cl. 26.2.1 and 34.2.4.3)

  • τbd = 1.2 × 1.6 = 1.92 N/mm² (M20, deformed bars)
  • Ld = 0.87 × 500 × 12 / (4 × 1.92) = 680 mm ≤ available 1100 − 50 = 1050 mm ✓ (straight bars are enough)

Bearing at the column base (cl. 34.4)

  • Actual = 1800 × 10³ / (400 × 400) = 11.25 N/mm²
  • Permissible = 0.45 fck √(A1/A2), with √(A1/A2) capped at 2 → 0.45 × 20 × 2 = 18 N/mm² ✓ (no dowel design needed for bearing; extend column bars into the footing anyway)
Reinforcement plan and bar bending schedule for a 2.6 m isolated footing with 20 bars of 12 mm each way, 88.9 kg of steel
Bottom mesh, bar bending schedule and quantities for footing F1.

Check your own footing

The checker below runs the same steps and clauses as the worked example for a square column on a square footing with a concentric load. Change the depth or bar spacing until every row turns green.

Isolated Footing Checker (IS 456:2000)
Square column, square footing, concentric axial load, no moments. Load factor 1.5, cover 50 mm. A learning and checking aid only; final designs need a qualified engineer’s review.

Common mistakes in isolated footing design and on site

  • Sizing the area with factored load. SBC is a service value. Using 1.5P gives an oversized footing; using P without self-weight gives an undersized one.
  • Stopping at the bending check. As the example shows, bending needed 246 mm but shear needed over 530 mm.
  • Checking one-way shear with the wrong pt. τc depends on the steel actually provided at that section. A designer who checks shear before choosing bars has to come back and recheck.
  • Cover blocks missing on site. Bars resting on the PCC have zero cover. That is exactly where the footing is wet for its whole life. Use 50 mm cover blocks at about 1 m centres.
  • Column starter bars not tied to the mesh. Starters must be L-bent, sit on the bottom mesh and be held by at least two ties in the footing depth so they do not move during the pour.
  • Casting on loose or wet soil. The SBC in the design assumes undisturbed ground. Remove loose soil and slush, and cast the PCC bed the same day the excavation is approved.

When this simple method is not enough

This procedure assumes an axial load with uniform soil pressure. Use a full eccentric-footing design when the column carries a significant moment (frames, wind or seismic load cases, or edge columns), when two footings overlap and should be combined, or when the soil report gives settlement limits rather than just an SBC. Sloped (trapezoidal) footings save concrete but need the shear and bending checks at several sections. Footings for structures above 4 storeys or in seismic zones IV and V should always be designed and checked by a qualified structural engineer.

FAQ

What is the minimum depth of an isolated footing as per IS 456?

IS 456 cl. 34.1.2 requires a thickness at the edge of at least 150 mm for footings on soil. In practice, one-way and punching shear set a much greater depth, typically 400 to 700 mm for building columns.

Where is the critical section for bending in a footing?

At the face of the column for a concrete column (IS 456 cl. 34.2.3.2). Each projection is treated as a cantilever loaded by the net upward soil pressure.

Where are one-way and punching shear checked?

One-way shear is checked at a distance d from the column face (cl. 34.2.4.1(a)). Punching shear is checked on a perimeter at d/2 from the column face (cl. 31.6.1), with permissible stress ks × 0.25√fck.

What is the minimum steel in a footing?

Footings follow the slab rule (cl. 34.5.1 and 26.5.2.1): 0.12% of the gross cross-section for HYSD bars (0.15% for mild steel), in each direction.

What clear cover is used for footings?

A minimum of 50 mm for footings (IS 456 cl. 26.4.2.2), measured from the bottom bars to the concrete surface, not to the PCC.

How this was checked: every number in the worked example was recomputed independently in code from IS 456:2000 (Annex G, Table 19, cl. 26, 31.6, 34) and matches the checker on this page. Clause numbers refer to IS 456:2000 with amendments. This article teaches the method; site designs must use project loads, the soil investigation report and a qualified engineer’s review.

Stop calculating by hand — go Pro

Unlock an ad-free experience plus a growing library of ready-to-use civil-engineering calculators, IS-code cheat-sheets and formula PDFs. From just ₹99.

Go Pro →

Discover more from The Civil Studies

Subscribe to get the latest posts sent to your email.

Fuel Free Learning Support TheCivilStudies

Keep civil engineering knowledge free — articles, calculators, and practical site guides for everyone.

Choose an amount

100% Secure · Powered by Cashfree

TheCivilStudies Team
TheCivilStudies Team

TheCivilStudies is an independent civil-engineering learning site from India. Our guides explain IS-code provisions, formulas, worked examples and site practice for students and working site engineers. Calculations are checked against the relevant Indian Standard, and articles are updated when codes or practice change. Spotted an error? Tell us in the comments and we will fix it.

Articles: 444