Steel design is mostly about finding every way a member or a joint can fail, working out the strength for each, and taking the smallest. A plate in tension, for example, can yield along its length, tear across the bolt holes or pull out as a block. The weakest of the three is its design strength.
The topics follow the order of the official GATE Civil Engineering syllabus, with connections placed first because every member design depends on them. Stresses are in N/mm² and dimensions in mm. For the other subjects, see the GATE, ESE and SSC JE preparation guide.
What the syllabus asks
| Exam | Syllabus wording |
|---|---|
| GATE CE, Steel Structures | Working stress and limit state design concepts; design of tension and compression members, beams and beam-columns, column bases; connections: simple and eccentric, beam-column connections, plate girders and trusses; concept of plastic analysis: beams and frames |
| ESE Civil Paper I | Design of steel structures: principles of working stress methods, design of tension and compression members, design of beams and beam-column connections, built-up sections, girders, industrial roofs, principles of ultimate load design |
| SSC JE, Steel Design | Steel design and construction of steel columns, beams, roof trusses and plate girders |
1. Limit state design and material properties
In simple words: In the working stress method the stress under the actual loads is kept below a fixed fraction of the yield stress. In the limit state method the loads are multiplied up, the material strengths are divided down, and the member is checked at the point of failure. IS 800:2007 uses the limit state method.

| Quantity | Value |
|---|---|
| Structural steel E250 (Fe 410) | fy = 250 N/mm², fu = 410 N/mm² |
| Modulus of elasticity | E = 2 × 105 N/mm² |
| Partial safety factor, yielding and buckling | γm0 = 1.10 |
| Partial safety factor, rupture at ultimate stress | γm1 = 1.25 |
| Partial safety factor, bolts | γmb = 1.25 |
| Partial safety factor, welds | γmw = 1.25 for shop welds, 1.50 for field welds |
| Bolt of grade 4.6 | fub = 400 N/mm², fyb = 240 N/mm² |
The load factors are the same as in concrete design: 1.5 (DL + LL), 1.5 (DL + WL) and 1.2 (DL + LL + WL). In the bolt grade 4.6, the first number times 100 is the ultimate strength, and the second is the ratio of yield to ultimate strength.
2. Bolted connections
In simple words: A bolt in a lap joint can fail in two ways: the bolt itself can be cut across (shear), or the plate around the bolt can be crushed (bearing). The strength of the bolt is the smaller of the two.
Where you see it: Trusses, towers and industrial sheds are bolted on site because bolting is fast and needs no skilled welder at height. The pitch and edge distance rules below are what the fabricator checks before drilling.
| Quantity | Formula or rule |
|---|---|
| Bolt hole diameter | Bolt diameter + 1 mm (12 to 14 mm bolts), + 2 mm (16 to 24 mm), + 3 mm (above 24 mm) |
| Minimum pitch | 2.5 × bolt diameter |
| Maximum pitch | 16t or 200 mm in tension; 12t or 200 mm in compression |
| Minimum edge distance | 1.7 × hole diameter for sheared edges; 1.5 × for rolled or machine-cut edges |
| Net tensile area of a bolt at the threads | Anb = 0.78 × π d² / 4 |
| Design shear strength of a bolt | Vdsb = (fub / √3)(nn Anb + ns Asb) / γmb |
| Design bearing strength of a bolt | Vdpb = 2.5 kb d t fu / γmb |
| kb | The smallest of e / 3d0, p / 3d0 − 0.25, fub / fu and 1.0 |
nn is the number of shear planes through the threads and ns the number through the shank. t is the thinner thickness being joined, d0 the hole diameter, e the end distance and p the pitch. High strength friction grip (HSFG) bolts work differently: they clamp the plates so tightly that the load is carried by friction, with no slip.
Example. Find the design shear strength of an M20 bolt of grade 4.6 in single shear, with the threads in the shear plane.
- Anb = 0.78 × π × 20² / 4 = 245 mm².
- Vdsb = (400 / √3) × 245 / 1.25 = 45 300 N = 45.3 kN.
- In double shear the value doubles to 90.5 kN, and bearing on the plate usually governs instead.
3. Welded connections
In simple words: A fillet weld is a triangle of weld metal laid in the corner between two plates. It fails in shear across its thinnest part, the throat, so its strength is the throat area times the shear strength of the weld.
| Quantity | Formula or rule |
|---|---|
| Effective throat thickness | tt = 0.7 × size of weld (for plates at 60° to 90°) |
| Effective length | Actual length − 2 × size of weld |
| Minimum length | 4 × size of weld |
| Design strength of a fillet weld | fwd = fu / (√3 γmw), on the throat area |
| Minimum size, thicker plate up to 10 mm | 3 mm |
| Minimum size, thicker plate 10 to 20 mm | 5 mm |
| Minimum size, thicker plate 20 to 32 mm | 6 mm |
| Maximum size, square edge | Plate thickness − 1.5 mm |
| Maximum size, rounded edge of a rolled section | ¾ of the thickness of the edge |
| Minimum overlap in a lap joint | 4 × thickness of the thinner plate, or 40 mm |
For E250 steel and a shop weld, fwd = 410 / (√3 × 1.25) = 189 N/mm². A butt weld with full penetration is as strong as the plates it joins and needs no separate check.
Example. A 6 mm shop fillet weld has an effective length of 200 mm. Find its design strength.
- Throat thickness = 0.7 × 6 = 4.2 mm. Throat area = 4.2 × 200 = 840 mm².
- Strength = 840 × 189 = 159 000 N = 159 kN.
4. Tension members
In simple words: A tension member is pulled along its length. It can fail by stretching excessively along its whole length (yielding of the gross section), by tearing where bolt holes have reduced the area (rupture of the net section), or by a block of material pulling out at the connection (block shear).
Where you see it: The bottom chord and some diagonals of a roof truss, the bracing of a steel building, the hangers of a suspension bridge and the tie rod of an arch.
| Quantity | Formula |
|---|---|
| Yielding of the gross section | Tdg = Ag fy / γm0 |
| Rupture of the net section, plates | Tdn = 0.9 An fu / γm1 |
| Rupture of the net section, single angle | Tdn = 0.9 Anc fu / γm1 + β Ago fy / γm0 |
| Net area with staggered holes | An = [b − n dh + Σ(p² / 4g)] t |
| Maximum slenderness ratio, member always in tension | 400 |
The design strength is the least of yielding, rupture and block shear. In the staggered hole formula, p is the stagger pitch along the load and g is the gauge across it. An angle connected by one leg is less effective than its area suggests, because the outstanding leg is not directly loaded. This is called shear lag.
Example. A plate 200 mm wide and 10 mm thick of E250 steel is connected by one line of two M20 bolts across its width (22 mm holes). Find its design tensile strength, ignoring block shear.
- Yielding: Tdg = 200 × 10 × 250 / 1.10 = 454 500 N = 454.5 kN.
- Net area = (200 − 2 × 22) × 10 = 1560 mm².
- Rupture: Tdn = 0.9 × 1560 × 410 / 1.25 = 460 500 N = 460.5 kN.
- The smaller value governs: 454.5 kN.
5. Compression members
In simple words: A steel column rarely fails by crushing. It is slender, so it buckles sideways long before the steel yields. Its strength therefore depends on its slenderness ratio, the effective length divided by the least radius of gyration.
Where you see it: Building columns, truss top chords and struts. Two angles or channels are often joined by lacing or battens to make one built-up column that is stiff about both axes.
| Quantity | Formula or value |
|---|---|
| Design compressive strength | Pd = Ae fcd |
| Slenderness ratio | K L / r |
| Euler buckling stress | fcc = π² E / (K L / r)² |
| Non-dimensional slenderness | λ = √(fy / fcc) |
| Imperfection factor α for buckling classes a, b, c, d | 0.21, 0.34, 0.49, 0.76 |
| Maximum slenderness, dead and imposed loads | 180 |
| Maximum slenderness, compression from wind or earthquake only | 250 |
| End conditions | Effective length K L |
|---|---|
| Both ends fixed against rotation and translation | 0.65 L |
| One end fixed, the other hinged | 0.8 L |
| Both ends hinged | 1.0 L |
| One end fixed, the other free | 2.0 L |
- fcd is read from the tables of IS 800 for the buckling class of the section and its slenderness ratio. The values are given in the question when needed.
- Lacing: inclined at 40° to 70° to the axis of the column; designed for a transverse shear of 2.5% of the column load; slenderness ratio of a lacing bar not more than 145; the effective slenderness of the laced column is increased by 5%.
- Battens: at least four along the column, so that it is divided into three bays or more; the effective slenderness is increased by 10%.
6. Beams
In simple words: A steel beam can fail by yielding in bending, by yielding of its web in shear, by twisting and moving sideways if its compression flange is not held (lateral torsional buckling), or by local buckling of its thin plates. A beam whose compression flange is held by a slab is called laterally supported and is the simplest case.
| Quantity | Formula |
|---|---|
| Classes of section | Plastic, compact, semi-compact and slender |
| Design bending strength, laterally supported, low shear | Md = βb Zp fy / γm0 |
| βb | 1.0 for plastic and compact sections; Ze / Zp for semi-compact sections |
| Upper limit, simply supported beam | Md ≤ 1.2 Ze fy / γm0 |
| Design shear strength | Vd = Av fyw / (√3 γm0) |
| Shear area of a rolled I-section | Av = overall depth × web thickness |
| High shear | When V exceeds 0.6 Vd, the bending strength is reduced |
| Laterally unsupported beam | Md = βb Zp fbd, with fbd less than fy / γm0 |
A plastic section can form a plastic hinge and rotate; a compact section can reach its plastic moment but cannot rotate much; a semi-compact section reaches yield only at its extreme fibre; a slender section buckles locally before yielding. The web must also be checked for buckling and crippling under concentrated loads, and the deflection must be within the limit, commonly span/300 for beams carrying elastic cladding and span/360 where there are brittle finishes.
Example. A laterally supported, simply supported beam is an ISMB 300 of E250 steel, with Zp = 651.7 × 10³ mm³ and Ze = 573.6 × 10³ mm³. The section is plastic. Find its design bending strength.
- Md = 1.0 × 651.7 × 10³ × 250 / 1.10 = 148.1 × 106 N·mm = 148.1 kN·m.
- Limit: 1.2 × 573.6 × 10³ × 250 / 1.10 = 156.4 kN·m, which is higher, so 148.1 kN·m stands.
7. Beam-columns and column bases
In simple words: A beam-column carries axial load and bending together, as almost every column in a rigid frame does. A column base is the steel plate that spreads the column load onto the concrete foundation, because concrete is far weaker than steel.
| Quantity | Formula |
|---|---|
| Beam-column, section strength (conservative check) | N / Nd + My / Mdy + Mz / Mdz ≤ 1.0 |
| Area of a slab base | Factored column load / bearing strength of the concrete |
| Bearing strength of concrete under a base plate (IS 800) | 0.6 fck; many designers use 0.45 fck |
| Thickness of a slab base | ts = √[2.5 w (a² − 0.3 b²) γm0 / fy], not less than the flange thickness |
In the slab base formula, w is the pressure under the plate and a and b are the larger and smaller projections of the plate beyond the column. A slab base is used for axial load. A gusseted base, with gusset plates and angles, is used for heavier loads or where there is a moment.
8. Plate girders and trusses
In simple words: When the largest rolled beam is not strong enough, a deep beam is built up from plates: two flanges to carry the bending and a thin, deep web to carry the shear. That is a plate girder. A truss does the same job with separate members instead of a solid web.
Where you see it: Plate girders carry railway bridges, crane gantries and transfer beams in buildings. Roof trusses span factory sheds and warehouses.
- The flanges resist almost all the bending moment and the web resists almost all the shear.
- A thin, deep web would buckle, so it is stiffened: transverse (vertical) stiffeners prevent buckling in shear, longitudinal stiffeners prevent buckling in bending, and bearing stiffeners are placed under concentrated loads and at the supports.
- For a web with transverse stiffeners only, the depth to thickness ratio d / tw is limited to 200 for serviceability.
- In a roof truss, the top chord (rafter) is in compression and the bottom chord (tie) is in tension under gravity load. Wind uplift can reverse these forces, which is why light roof trusses are checked for both.
9. Plastic analysis
In simple words: When the most stressed section of a steel beam yields right through its depth, it cannot take any more moment, but it does not break. It turns like a rusty hinge while holding that moment. This is a plastic hinge. An indeterminate beam collapses only when enough hinges have formed to turn it into a mechanism, so it has a reserve of strength beyond first yield.
| Quantity | Formula or value |
|---|---|
| Plastic moment | Mp = fy Zp |
| Shape factor | Zp / Ze = Mp / My |
| Shape factor, rectangle | 1.5 |
| Shape factor, solid circle | 1.7 |
| Shape factor, diamond | 2.0 |
| Shape factor, triangle | 2.34 |
| Shape factor, rolled I-section about its major axis | About 1.12 to 1.14 |
| Number of plastic hinges for complete collapse | Degree of static indeterminacy + 1 |
| Beam and loading | Collapse load |
|---|---|
| Simply supported, central point load | Wu = 4 Mp / L |
| Simply supported, UDL | wu = 8 Mp / L² |
| Fixed at both ends, central point load | Wu = 8 Mp / L |
| Fixed at both ends, UDL | wu = 16 Mp / L² |
| Propped cantilever, central point load | Wu = 6 Mp / L |
| Propped cantilever, UDL | wu = 11.66 Mp / L² |
- Upper bound (kinematic) theorem: a load found from any assumed mechanism is greater than or equal to the true collapse load.
- Lower bound (static) theorem: a load found from any moment diagram that is in equilibrium and nowhere exceeds Mp is less than or equal to the true collapse load.
- Collapse loads are found by equating the work done by the loads to the energy absorbed at the hinges.
Example. A beam fixed at both ends spans 6 m and has a plastic moment capacity of 150 kN·m. Find the uniformly distributed load at collapse.
- Hinges form at the two supports and at mid-span.
- wu = 16 Mp / L² = 16 × 150 / 6² = 66.7 kN/m.
- The same beam simply supported would collapse at 8 × 150 / 36 = 33.3 kN/m. Fixing the ends doubles the collapse load.
The plastic section modulus and the behaviour of steel beyond yield are easier to follow after strength of materials, topic by topic and the stress-strain curve of mild steel. Indeterminacy is explained in structural analysis, topic by topic.
Common mistakes
- Using the gross area of a bolt when the threads are in the shear plane. Use 0.78 times the gross area.
- Using the bolt diameter in place of the hole diameter when finding the net area of a plate.
- Dividing rupture strength by γm0 (1.10). Rupture uses γm1 (1.25) and the ultimate stress; yielding uses γm0 and the yield stress.
- Taking the size of a fillet weld as its throat. The throat is 0.7 times the size.
- Using the theoretical effective lengths (0.5 L and 0.7 L) in a code-based question. IS 800 recommends 0.65 L and 0.8 L.
- Forgetting the 1.2 Ze fy / γm0 limit on the bending strength of a simply supported beam.
Frequently asked questions
Which steel design topics are most important for GATE?
Bolt and weld strength, the tensile strength of a plate or angle, plastic analysis (shape factor and collapse load) and the bending strength of a laterally supported beam give most of the questions. Plate girders and column bases usually give short theory questions.
Do I need the steel tables in the exam?
No. Section properties and the design compressive stress fcd are given in the question when needed. Remember the safety factors, the bolt and weld rules and the effective length factors.
Is the working stress method still asked?
GATE follows the limit state method of IS 800:2007. ESE and SSC JE can still ask direct questions from the older working stress approach, such as a permissible axial tensile stress of 0.6 fy and a permissible bending stress of 0.66 fy.
Why is the shape factor of an I-section so low?
Most of the material of an I-section is already in the flanges, far from the neutral axis, so it is nearly fully used when the extreme fibre first yields. There is little material left near the centre to give extra capacity. A rectangle has much more material near the neutral axis and so has a larger reserve.
Unlock an ad-free experience plus a growing library of ready-to-use civil-engineering calculators, IS-code cheat-sheets and formula PDFs. From just ₹99.