RCC design is the one subject where the examiner expects you to remember numbers from a code. The good news is that the list is short and it does not change from year to year. This sheet collects the limit state formulas and clause values of IS 456:2000 in the order you would use them in a design.
Stresses are in N/mm² and dimensions in mm unless stated. For the code itself in plain language, read the IS 456:2000 guide. For the other subjects, see the GATE, ESE and SSC JE preparation guide.
Material properties and safety factors
In simple words: Concrete and steel are never trusted at their full test strength. The code divides the strengths by safety factors, so design uses lower values than the cube and bar tests give.

Where it is used: A 150 mm cube tested at 28 days gives fck. The beam is then designed with only 0.447 fck, to allow for site workmanship and the difference between a cube and a real member.
| Quantity | Formula or value |
|---|---|
| Modulus of elasticity of concrete | Ec = 5000 √fck |
| Flexural tensile strength | fcr = 0.7 √fck |
| Modulus of elasticity of steel | Es = 2 × 105 N/mm² |
| Partial safety factor, concrete | γc = 1.5 |
| Partial safety factor, steel | γs = 1.15 |
| Design compressive stress in concrete | 0.67 fck / 1.5 = 0.447 fck |
| Design stress in steel | fy / 1.15 = 0.87 fy |
| Maximum strain in concrete in bending | 0.0035 |
| Minimum strain in tension steel at failure | 0.002 + 0.87 fy / Es |
Load combinations for the limit state of collapse
In simple words: Loads are multiplied by factors greater than 1 before design, so the structure has a margin against overloading.
Where it is used: A slab carrying 4 kN/m² of dead load and 3 kN/m² of live load is designed for 1.5 × 7 = 10.5 kN/m².
| Combination | Factored load |
|---|---|
| Dead + live | 1.5 (DL + LL) |
| Dead + wind or earthquake | 1.5 (DL ± WL) or 1.5 (DL ± EL) |
| Dead + wind or earthquake, when stability governs | 0.9 DL ± 1.5 WL or 0.9 DL ± 1.5 EL |
| Dead + live + wind or earthquake | 1.2 (DL + LL ± WL) or 1.2 (DL + LL ± EL) |
For the limit state of serviceability the factors are 1.0 for DL + LL and for DL + WL, and 1.0 DL + 0.8 LL + 0.8 WL when all three act together.
Flexure: singly reinforced rectangular section
In simple words: In a beam that sags, concrete at the top carries compression and steel at the bottom carries tension. The beam is kept under-reinforced so that the steel yields first and the beam shows cracks and deflection before it fails.
Where it is used: This is the calculation behind every beam and slab schedule: given the moment, find the depth and the area of bottom steel.
| Quantity | Formula |
|---|---|
| Compressive force in concrete | C = 0.36 fck b xu, acting at 0.42 xu from the top |
| Tensile force in steel | T = 0.87 fy Ast |
| Depth of neutral axis | xu = 0.87 fy Ast / (0.36 fck b) |
| Lever arm | z = d − 0.42 xu |
| Moment of resistance (under-reinforced) | Mu = 0.87 fy Ast (d − 0.42 xu) |
| Same, in terms of steel area | Mu = 0.87 fy Ast d [1 − Ast fy / (b d fck)] |
| Limiting moment of resistance | Mu,lim = 0.36 fck b xu,max (d − 0.42 xu,max) |
| Steel grade | xu,max / d | Mu,lim |
|---|---|---|
| Fe250 | 0.53 | 0.148 fck b d² |
| Fe415 | 0.48 | 0.138 fck b d² |
| Fe500 | 0.46 | 0.133 fck b d² |
- xu less than xu,max: under-reinforced. Steel yields first and failure gives warning. This is what the code wants.
- xu equal to xu,max: balanced section.
- xu more than xu,max: over-reinforced. Not permitted; redesign the section, and if a moment capacity is asked, limit it to Mu,lim.
For a flanged beam, the effective flange width is bf = l0/6 + bw + 6 Df for a T-beam and bf = l0/12 + bw + 3 Df for an L-beam, where l0 is the distance between points of zero moment. It cannot exceed the actual width available.
Reinforcement limits
In simple words: Too little steel and the member snaps suddenly when the concrete cracks. Too much and the bars are so crowded that concrete cannot be placed and compacted around them. The code sets both limits.
Where it is used: Checking a drawing or a bar bending schedule: is the column steel between 0.8% and 6%, are the ties close enough, is the slab steel above the minimum?
| Member | Rule |
|---|---|
| Beam, minimum tension steel | Ast / (b d) = 0.85 / fy |
| Beam, maximum tension or compression steel | 4% of b D each |
| Beam, side face steel | Needed when the web is deeper than 750 mm: 0.1% of the web area, spacing not more than 300 mm |
| Slab, minimum steel | 0.15% of gross area for mild steel, 0.12% for high strength deformed bars |
| Slab, bar size and spacing | Bar diameter not more than D/8. Main bars at 3d or 300 mm, distribution bars at 5d or 450 mm, whichever is less |
| Column, longitudinal steel | 0.8% to 6% of the gross area (4% is the practical limit where bars are lapped) |
| Column, bars | Minimum 12 mm diameter; at least 4 bars in a rectangular column and 6 in a circular column |
| Column, lateral ties | Diameter not less than ¼ of the largest main bar and not less than 6 mm. Pitch not more than the least lateral dimension, 16 times the smallest main bar diameter, or 300 mm |
Shear
In simple words: Near the supports a beam tends to crack diagonally. Concrete resists some of this shear and stirrups carry the rest.
Where it is used: Stirrups are spaced closer near the supports, where shear is highest, and wider near mid-span. Missing or widely spaced stirrups are a common cause of sudden beam failure.
| Quantity | Formula or value |
|---|---|
| Nominal shear stress | τv = Vu / (b d) |
| Design shear strength of concrete, τc | From Table 19; depends on the grade of concrete and the percentage of tension steel |
| Shear to be carried by stirrups | Vus = Vu − τc b d |
| Vertical stirrups | Vus = 0.87 fy Asv d / sv |
| Minimum shear reinforcement | Asv / (b sv) ≥ 0.4 / (0.87 fy) |
| Maximum stirrup spacing | 0.75 d for vertical stirrups, and never more than 300 mm |
| Grade of concrete | M20 | M25 | M30 | M35 | M40 and above |
|---|---|---|---|---|---|
| τc,max (N/mm²) | 2.8 | 3.1 | 3.5 | 3.7 | 4.0 |
- If τv is more than τc,max, the section must be made larger. No amount of stirrups can fix it.
- If τv is less than τc, provide minimum shear reinforcement.
- In solid slabs the nominal shear stress must not exceed half of τc,max, and τc is multiplied by a factor k that depends on the slab thickness.
- The critical section for shear is at a distance d from the face of the support when the support reaction puts the end of the beam in compression.
Bond, development length and laps
In simple words: A bar can carry load only if it is gripped by enough concrete. The development length is the embedded length needed for the bar to reach its full strength without slipping.
Where it is used: Lap lengths where bars are joined, anchorage of beam bars into columns, and the length of starter bars left for the next lift all come from this.
| Quantity | Formula or value |
|---|---|
| Development length | Ld = φ σs / (4 τbd), with σs = 0.87 fy at full design stress |
| Deformed bars | Increase τbd by 60% |
| Bars in compression | Increase τbd by a further 25% |
| Lap in flexural tension | Ld or 30φ, whichever is greater |
| Lap in direct tension | 2 Ld or 30φ, whichever is greater |
| Lap in compression | Ld in compression, but not less than 24φ |
| Anchorage value of a standard U hook | 16φ |
| Anchorage value of a standard 90° bend | 8φ (4φ for every 45° of bend, up to 16φ) |
| Grade of concrete | M20 | M25 | M30 | M35 | M40 and above |
|---|---|---|---|---|---|
| τbd for plain bars in tension (N/mm²) | 1.2 | 1.4 | 1.5 | 1.7 | 1.9 |
The lap length guide explains each term, and the lap length calculator gives Ld and lap lengths for any bar and grade.
Columns
In simple words: A column mainly carries compression, shared between the concrete and the longitudinal bars. No load is ever perfectly central, so a minimum eccentricity is always assumed.
Where it is used: Finding the load a column can safely carry, or the size and steel needed for a given load. Ties stop the main bars from buckling outward.
| Quantity | Formula |
|---|---|
| Short column | Both lex/D and ley/b are less than 12 |
| Minimum eccentricity | emin = l/500 + D/30, but not less than 20 mm |
| Short axially loaded column with ties | Pu = 0.4 fck Ac + 0.67 fy Asc |
| Column with helical reinforcement | 1.05 times the strength of the same column with ties |
The axial load formula applies when the minimum eccentricity is not more than 0.05 times the lateral dimension. Ac is the area of concrete, that is, the gross area minus the area of steel.
Slabs and deflection control
In simple words: A slab that is too thin sags, cracks the partitions resting on it and feels unsafe, even if it is strong enough. The span to depth ratio keeps the deflection within limits without a long calculation.
Where it is used: Choosing the slab thickness at the start of a design: a simply supported one-way slab spanning 3.5 m needs an effective depth of roughly 3500 / 20 = 175 mm before the modification factors are applied.
| Item | Rule |
|---|---|
| One-way slab | ly / lx greater than 2 |
| Two-way slab | ly / lx of 2 or less, supported on all four sides |
| Basic span to effective depth ratio | Cantilever 7, simply supported 20, continuous 26 (for spans up to 10 m) |
| Spans above 10 m | Multiply the basic ratio by 10 / span in metres (not for cantilevers, which need a deflection calculation) |
| Final deflection limit | Span / 250 |
| Deflection after partitions and finishes | Span / 350 or 20 mm, whichever is less |
The basic ratio is then multiplied by modification factors for tension steel and compression steel. See one-way vs two-way slab and the full slab design example.
Cover and minimum grade of concrete
In simple words: Cover is the layer of concrete outside the steel. It protects the bars from rust and fire, and it must be thicker in harsher surroundings.
Where it is used: Cover blocks of the right thickness are fixed before concreting. Too little cover is the main reason for rusted bars and spalling in coastal buildings.
| Exposure | Nominal cover (mm) | Minimum grade for RCC |
|---|---|---|
| Mild | 20 | M20 |
| Moderate | 30 | M25 |
| Severe | 45 | M30 |
| Very severe | 50 | M35 |
| Extreme | 75 | M40 |
In addition, the cover to column bars should not be less than 40 mm and the cover in footings not less than 50 mm. Member-wise values are in clear cover in RCC as per IS 456 and in the IS 456 quick tables.
Footings: critical sections
In simple words: A footing spreads the column load over the soil. It can fail in three ways: by bending, by shear across its width, or by the column punching through it.
Where it is used: The depth of an isolated footing is usually decided by punching shear, and its bottom steel by the bending moment at the face of the column.
| Check | Critical section |
|---|---|
| Bending moment | At the face of the column |
| One-way shear | At a distance d from the face of the column |
| Two-way (punching) shear | At a distance d/2 from the face of the column, all round |
| Permissible punching shear stress | ks × 0.25 √fck, where ks = 0.5 + βc, not more than 1 |
βc is the ratio of the short side to the long side of the column. The thickness at the edge of a footing on soil should not be less than 150 mm. A complete design is worked out in isolated footing design as per IS 456.
Solved example 1: limiting moment of a beam
Question. A rectangular beam is 230 mm wide with an effective depth of 450 mm. The materials are M20 concrete and Fe415 steel. Find the limiting moment of resistance and the steel area needed for it.
- xu,max = 0.48 d = 0.48 × 450 = 216 mm.
- Mu,lim = 0.138 fck b d² = 0.138 × 20 × 230 × 450² = 128.5 × 106 N·mm = 128.5 kN·m.
- Ast,lim = 0.36 fck b xu,max / (0.87 fy) = 0.36 × 20 × 230 × 216 / (0.87 × 415) = 991 mm².
That is about 0.96% of b d, the well-known limiting steel percentage for M20 and Fe415.
Solved example 2: development length
Question. Find the development length in tension of a 16 mm Fe500 bar in M25 concrete.
- τbd for M25 is 1.4 N/mm² for plain bars. For deformed bars, 1.4 × 1.6 = 2.24 N/mm².
- Ld = φ × 0.87 fy / (4 τbd) = 16 × 0.87 × 500 / (4 × 2.24) = 777 mm.
- That is about 49 times the bar diameter.
Common mistakes
- Using the overall depth D where the effective depth d is needed, or the other way round. Steel percentages for slabs and columns use the gross section; flexure and shear use d.
- Forgetting the 60% increase in bond stress for deformed bars, which makes Ld far too long.
- Calculating a moment of resistance for an over-reinforced section with the actual xu instead of limiting it to xu,max.
- Mixing up τc (Table 19, depends on steel percentage) and τc,max (Table 20, depends only on the grade).
- Taking the punching shear section at d instead of d/2, or one-way shear at d/2 instead of d.
- Applying factored loads to a serviceability check such as deflection.
Frequently asked questions
Is the working stress method still asked?
Rarely in GATE, which follows the limit state method. ESE and SSC JE still ask a few direct questions, such as the modular ratio m = 280 / (3 σcbc) and permissible stresses, so learn those values as well.
Do I need to remember Table 19 for τc?
No. When a question needs τc, the value or the table is given. You are expected to remember τc,max, the bond stresses, the limiting neutral axis depths and the steel limits.
Which value of Mu,lim should I use for Fe250, 0.148 or 0.149?
Both appear in textbooks. Working it out from xu,max = 0.53d gives 0.1484, which rounds to 0.148; IS 456 itself tabulates 0.148. Use 0.148 unless the question says otherwise.
Are these values the same in the 2000 code and its amendments?
The values on this page are those of IS 456:2000 as commonly taught and examined. Amendments have changed a few details, so for design work always read the current code with its amendments.
Unlock an ad-free experience plus a growing library of ready-to-use civil-engineering calculators, IS-code cheat-sheets and formula PDFs. From just ₹99.




